A roll no longer tears down live views on the pod it replaced

Every rolling deploy leaves a short window in which a message is still addressed to a pod that has gone. The framework already handled that window in the right way — the delivery is retried, and each retry re-resolves the target so a later attempt lands on the surviving pod. What went wrong was the verdict after the retries, and that verdict is what decides whether the sender keeps going.

A sender told "transient" keeps its recovery machinery armed and resubscribes; a sender told "failed" tears it down for good. So the classification of one window decided whether a live view, a mirror or a sync stream came back after a roll — or stayed dead until the page was reloaded.

The router's rule for that verdict is a good one, and it is deliberately strict: only a condition that is a lifecycle transition by construction counts as transient, and anything unrecognised stays permanent, so a real defect is still reported as one. Three conditions qualified — the grain directory mid-handoff, the host going away, the process's container being disposed. The last one was recognised by two exception types, and the two ways Orleans actually reports a departed pod are neither of them:

what Orleans says what it means
Unable to connect to S10.244.2.223:11111:148812047 … (host unreachable, connection refused) nothing is listening at that address any more
The target silo is no longer active: target was …:146524552, but this silo is …:146534005 the pod restarted and reclaimed its address; callers still hold the old incarnation

Both are statements about one specific pod incarnation — the address carries a generation stamp — so neither can start working again, and the only cure is the re-resolve that the retry already performs. Both are now classified as the lifecycle transition they are.

A timeout deliberately still counts as permanent, and the difference is the point: a timeout means the target accepted the connection and did not answer, which is plausibly a wedge rather than a restart, and telling a sender to keep retrying a wedge is a storm.

Measured

Two production incidents, 191 and 3,959 occurrences, recorded across 27 pods over four weeks. They are one root seen through two logs — one fingerprinted on the router's own verdict, the other on Orleans' per-attempt addressing log, which the retries multiply. The full account, including the shapes that are still open, is in A departed silo is not a delivery defect.